{"product_id":"wood-stabilizing-chamber","title":"Wood Stabilizing Chamber","description":"\u003ch2 style=\"text-align: center;\"\u003e\u003cspan\u003e\u003cstrong\u003eWood Stabilizing Chamber \u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003csmall\u003e(Comes with \u003cspan data-mce-fragment=\"1\"\u003e30 Day\u003c\/span\u003e Limited Warranty)\u003c\/small\u003e\u003c\/p\u003e\n\u003cp\u003eThis is a complete BestValueVac® vacuum chamber setup designed built and 100% tested in Naperville, Illinois. This PVC chamber is ideal for woodworkers who use wood stabilization. With our unique patent-pending gasket design (\u003cspan data-mce-fragment=\"1\"\u003ePatent #\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e9475627\u003c\/span\u003e) this chamber is sure to last 10,000 uses with proper care and maintenance.\u003c\/p\u003e\n\u003cp\u003eThe gasket itself is reversible (doubling the life of our system) allowing customers to instantly take it off and flip it over. No adhesives are used! Our simple gasket design even allows you to place the lid on the chamber somewhat off-center and still pull a full vacuum.\u003c\/p\u003e\n\u003cp\u003eThis is a feature that most other vacuum chambers do not offer. The maximum allowed temperature of this chamber is 160f. The components of this chamber are rated at higher temperatures however as a vacuum vessel we limit maximum operational temperature to 160f. Every chamber is tested prior to shipping to lose no more than 2.5Hg\/24hrs.\u003c\/p\u003e\n\u003cp\u003e-Please refer to these charts for vacuum specifications at altitude and conversions:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0078\/8814\/2451\/files\/EVU-ATMOSPHERIC-PRESSURE.png?v=1575325776\" target=\"_blank\"\u003eVacuum at Altitude Chart\u003c\/a\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/farm8.staticflickr.com\/7255\/8157329906_4aa3e3762b.jpg\" target=\"_blank\"\u003eVacuum Conversion Chart\u003c\/a\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e Key Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eClear PVC Vessel 6\" diameter and 12\" Depth\u003c\/li\u003e\n\u003cli\u003eClear PVC Vessel 6\" diameter and 23\" Depth\u003c\/li\u003e\n\u003cli\u003eHighly Durable and Reversible Silicone Gasket\u003c\/li\u003e\n\u003cli\u003eGlycerin filled vacuum gauge\u003c\/li\u003e\n\u003cli\u003eUser-friendly vacuum connections that fit most vacuum pumps on the market\u003c\/li\u003e\n\u003cli\u003e50 Micron Air filter for reducing airborne contaminants when releasing the vacuum\u003c\/li\u003e\n\u003cli\u003eSilicone vacuum pad\u003c\/li\u003e\n\u003cli\u003e5' of vacuum rated HVAC hose to pull a vacuum.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-eqfb\" colspan=\"2\"\u003eSpecifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eChamber Material\u003c\/td\u003e\n\u003ctd class=\"tg-s618\"\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eGasket Material\u003c\/td\u003e\n\u003ctd class=\"tg-s618\"\u003eSilicone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eLid Material\u003c\/td\u003e\n\u003ctd class=\"tg-s618\"\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lboi\"\u003eInternal Dimensions (ID)\u003c\/td\u003e\n\u003ctd class=\"tg-s618\"\u003e\n\u003cul\u003e\n\u003cli\u003e6\" Diameter x 12\" Depth\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e6\" Diameter x 23\" Depth\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eVacuum Gauge (Glycerin Filled)\u003c\/td\u003e\n\u003ctd class=\"tg-1od0\"\u003eInHG (0)-(-30)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eManifold Connections\u003c\/td\u003e\n\u003ctd class=\"tg-s618\"\u003e1\/4\" SAE and 1\/4\" FNPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eTemperature Rating\u003c\/td\u003e\n\u003ctd class=\"tg-s618\"\u003e160°F (65°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lboi\"\u003eAdditional Included Items\u003c\/td\u003e\n\u003ctd class=\"tg-s618\"\u003e\n\u003cul\u003e\n\u003cli\u003e5' \u003cspan data-mce-fragment=\"1\"\u003ePurple\u003c\/span\u003e Vacuum Rated HVAC Hose\u003c\/li\u003e\n\u003cli\u003ePlatinum Cured Silicone Pad\u003c\/li\u003e\n\u003cli\u003eBlack 50 Micron Air Filter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eWarranty Information:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eCustomers using solvents such as stabilization resins (MinWax™, Gator Venom™ etc.), alcohol and other polar solvents must use the vacuum pumps in conjunction \u003cb\u003ewith a cold trap for evacuations in excess of 5 minutes. (Excludes Cactus Juice™)\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIf the consumer is using the pump for prolonged periods of time exceeding 5 minutes \u003cb\u003ewe require that a cold trap is used or the pump warranty is void.\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003eThese stabilization resins have the ability to break down the internal components of the pump that are plastic resulting in a seized motor \u003cb\u003evoiding all warranties.\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003eWhen evacuation exceeds 5 minutes these solvents begin to vaporize and then re-condense in the vacuum pump reservoir. Once enough solvent re-condenses in the pump displacing the oil the plastic internal components may begin to warp, melt or seize. The use of a cold trap will condense the vapors \u003cb\u003e\u003ci\u003eprior\u003c\/i\u003e\u003c\/b\u003e to making their way to the vacuum pump preventing pump damage due to excessive use. Furthermore, Minwax Wood Hardener™ is not to be used with any vacuum pumps, \u003cstrong\u003eEVER.\u003c\/strong\u003e (A seized motor will result in the first use.)\u003c\/li\u003e\n\u003cli\u003eTo prevent these issues from happening to your process, change the Oil after each vacuum pump use, Even if the use time is only 5min.\u003c\/li\u003e\n\u003cli\u003eIf the chamber vessel is left exposed to stabilization resin for a prolonged period of time, crazing may occur at the bottom of the vessel. It's recommended to clean the chamber periodically of all stabilization resin to prevent these cracks from forming in the chamber.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eFor shipping info including Import\/Export details visit our Shipping link at the bottom of the page.\u003c\/b\u003e\u003c\/p\u003e","brand":"BVV","offers":[{"title":"6\" x 12\"","offer_id":47622360498314,"sku":"BVV6X12WSC","price":285.0,"currency_code":"USD","in_stock":true},{"title":"6\" x 23\"","offer_id":47622360531082,"sku":"BVV6X23WSC","price":368.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0578\/9378\/1642\/files\/BVV6X12WSC.jpg?v=1769634991","url":"https:\/\/shop.badowltool.com\/products\/wood-stabilizing-chamber","provider":"Bad Owl Tool","version":"1.0","type":"link"}